Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 59 Next »

Use this event to

Add steps to be displayed at the mobile device when collecting values for each individual document line.

Description

Steps at line level (collected for each individual line) requires a collectorConfiguration-Key to be declared in Reference Data.
This is unlike steps at header level, that allows steps to be declared directly in the OnGetReceiveOrderLines_OnAddStepsToAnyHeader event.


Line-level step are:

  • ..merged with existing workflow steps
  • ..declared as part of a collectorConfiguration-Key in Reference Data.
  • ..added by calling the Create_StepsByReferenceDataKey-function (Currently only once)
  • ..sorted by Id. Sorting can be changed using the <orderLineConfiguration><extraInformationConfiguration stepSorting="ById"/><orderLineConfiguration/> in mobile configuration.


Using _Steps-parameterUsing ConfigurationKey from ReferenceData
Easier syntax (Steps defined on-the-fly)More difficult to use (requires ConfigurationKey in ReferenceData)
Multiple subscribers to same OnAddSteps event is possible

Only a single subscriber must exist to same OnAddSteps event

Performance cost is 5%-10% per step added to order linesNo performance cost per order line
Minimum requirements are Mobile WMS 5.39 and Android App 1.8Minimum requirement is Mobile WMS 5.11



Template

    [EventSubscriber(ObjectType::CodeunitCodeunit::"MOB WMS Receive", 'OnGetReceiveOrderLines_OnAddStepsToAnyLine''', true, true)]
    local procedure OnGetReceiveOrderLines_OnAddStepsToAnyLine(_RecRef: RecordRefvar _BaseOrderLineElement: Record "MOB Ns BaseDataModel Element")
    begin
    end;


Example: Using _Steps-parameter

were

Example: Using ConfigurationKey from ReferenceData

(warning)  Currently Mobile WMS supports only one (custom) referenced key per Order Line, meaning only one customization may create StepsByReferenceDataKey at any time. This single one subscriber must set a Key that includes all steps for all other intended subscribers as well. This can only be done by knowing other customizations are in place and manually create a new RegistrationCollectorConfigurationKey that includes all steps.

    // [Example]: Add steps referenced by new RegistrationCollectorConfiguration-Key to line steps collectors
    [EventSubscriber(ObjectType::CodeunitCodeunit::"MOB WMS Receive", 'OnGetReceiveOrderLines_OnAddStepsToAnyLine''', true, true)]
    local procedure MyOnGetReceiveOrderLines_OnAddStepsToAnyLine(_RecRef: RecordRefvar _BaseOrderLineElement: Record "MOB NS BaseDataModel Element")
    begin
        _BaseOrderLineElement.Create_StepsByReferenceDataKey('CustomReceiveSteps');
    end;

    [EventSubscriber(ObjectType::CodeunitCodeunit::"MOB WMS Reference Data", 'OnGetReferenceData_OnAddRegistrationCollectorConfigurations''', true, true)]
    local procedure MyOnGetReferenceData_OnAddRegistrationCollectorConfigurations(var _Steps: Record "MOB Steps Element")
    begin
        _Steps.InitConfigurationKey('CustomReceiveSteps');

        _Steps.Create_DecimalStep(10000'CustomNetWeightGrams');
        _Steps.Set_header('Net Weight (Grams)');
        _Steps.Set_label('Net Weight (Grams):');
        _Steps.Set_helpLabel('Net Weight in Grams per Base Unit of Measure');
        _Steps.Set_minValue(0);
        _Steps.Set_maxValue(100000);
        _Steps.Set_performCalculation(true);
    end;



More examples


Version History

VersionChanges
MOB5.11Introduced
MOB5.39New _Steps parameter introduced
  • No labels