Use this event to

Excerpt

Add steps to be displayed at on the mobile device when collecting values for each individual document line.

Description

Steps at line level (collected for each individual line) requires a collectorConfiguration-Key to be declared in Reference Data.

...

Line-level step are:

  • ..merged with existing workflow steps
  • ..declared as part of Reference Data
  • ..added by calling the Create_StepsByReferenceDataKey-function 
  • ..sorted by Id. Sorting can be changed using the <orderLineConfiguration><extraInformationConfiguration stepSorting="ById"/><orderLineConfiguration/> in mobile configuration.


Only one key per order line:

  • You can have multiple keys with different steps. But just one key can be assigned to a line.
  • So you might need to create multiple keys, for the unique combinations of steps you want to collect.


Template

    [EventSubscriber(ObjectType::Codeunit, Codeunit::"MOB WMS CountPhys Invt Recording", 'OnGetCountOrderLinesOnGetPhysInvtRecordingLines_OnAddStepsToAnyLineOnAddStepsToPhysInvtRecordLine', '', true, true)]
    localprocedure OnGetCountOrderLines OnGetPhysInvtRecordingLines_OnAddStepsToAnyLineOnAddStepsToPhysInvtRecordLine(_RecRef: RecordRefPhysInvtRecordLine: Record "Phys. Invt. Record Line"; var _BaseOrderLineElement: Record "MOB NS BaseDataModel Element")
    begin
    end;


    // [Example]: Add steps referenced by new RegistrationCollectorConfiguration-Key to line steps collectors

    [EventSubscriber(ObjectType::Codeunit, Codeunit::"MOB WMS CountPhys Invt Recording", 'OnGetCountOrderLinesOnGetPhysInvtRecordingLines_OnAddStepsToAnyLineOnAddStepsToPhysInvtRecordLine', '', true, true)]
    localprocedure MyOnGetCountOrderLines MyOnGetPhysInvtRecordingLines_OnAddStepsToAnyLineOnAddStepsToPhysInvtRecordLine(_RecRef: RecordRefPhysInvtRecordLine: Record "Phys. Invt. Record Line"; var _BaseOrderLineElement: Record "MOB NS BaseDataModel Element")
    begin
        _BaseOrderLineElement.Create_StepsByReferenceDataKey('CustomCountSteps');
    end;


    [EventSubscriber(ObjectType::Codeunit, Codeunit::"MOB WMS Reference Data", 'OnGetReferenceData_OnAddRegistrationCollectorConfigurations', '', true, true)]
    localprocedure MyOnGetReferenceData_OnAddRegistrationCollectorConfigurations(var _Steps: Record "MOB Steps Element")
    begin
        _Steps.InitConfigurationKey('CustomCountSteps');

        _Steps.Create_DecimalStep(10000, 'CustomNetWeightGrams');
        _Steps.Set_header('Net Weight (Grams)');
        _Steps.Set_label('Net Weight (Grams):');
        _Steps.Set_helpLabel('Net Weight in Grams per Base Unit of Measure');
        _Steps.Set_minValue(0);
        _Steps.Set_maxValue(100000);
        _Steps.Set_performCalculation(true);
    end;


 