Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Use this event to

...

Steps at line level (collected for each individual line) requires a " collectorConfiguration"-Key to be declared in Reference Data.

This is unlike steps at header level, that allows steps to be declared directly in the OnGetMoveOrderLines_OnAddStepsToWarehouseMovementHeader event.

"Line" -level stepsstep are:

  • Are executed when values for each line is collected
  • Is ..merged with existing workflow steps
  • New steps is always ..declared as part of a collectorConfiguration-Key in Reference Data.
  • These new steps is ..added by calling the Create_StepsByReferenceDataKey-function (Currently only once)
  • Sort order for new steps will usually be ..sorted by Id but . Sorting can be modified changed using the the <orderLineConfiguration><extraInformationConfiguration stepSorting="ById"/><orderLineConfiguration/> tag in the  in mobile configuration file.


(advarsel)(warning) Currently Mobile WMS supports only one (custom) referenced key per Order Line, meaning only one customization may subscribe to this event at any time. This single one subscriber must set a Key that includes all steps for all other intended subscribers as well. This can only be done by knowing other customizations are in place and manually create a new RegistrationCollectorConfigurationKey that includes all steps (this will improve in a future version).

Template

    [EventSubscriber(ObjectType::CodeunitCodeunit::"MOB WMS Move", 'OnGetMoveOrderLines_OnAddStepsToWarehouseActivityLine''', true, true)]
    procedure OnGetMoveOrderLines_OnAddStepsToWarehouseActivityLine(_WhseActivityLine: Record "Warehouse Activity Line"; var _BaseOrderLineElement: Record "MOB NS BaseDataModel Element")
    begin
    end;


Example

    // [Example]: Add steps referenced by new RegistrationCollectorConfiguration-Key to line steps collectors
    [EventSubscriber(ObjectType::CodeunitCodeunit::"MOB WMS Move", 'OnGetMoveOrderLines_OnAddStepsToWarehouseActivityLine''', true, true)]
    procedure MyOnGetMoveOrderLines_OnAddStepsToAnyLine(_WhseActivityLine: Record "Warehouse Activity Line"; var _BaseOrderLineElement: Record "MOB NS BaseDataModel Element")
    begin
        with _BaseOrderLineElement do
            Create_StepsByReferenceDataKey('CustomMoveSteps', true);
    end;



    [EventSubscriber(ObjectType::CodeunitCodeunit::"MOB WMS Reference Data", 'OnGetReferenceData_OnAddRegistrationCollectorConfigurations''', true, true)]
    local procedure MyOnGetReferenceData_OnAddRegistrationCollectorConfigurations(var _Steps: Record "MOB Steps Element")
    begin
        with _Steps do begin
            InitConfigurationKey('CustomMoveSteps');

            Create_DecimalStep(10000'CustomNetWeightGrams');
            Set_header('Net Weight (Grams)');
            Set_label('Net Weight (Grams):');
            Set_helpLabel('Net Weight in Grams per Base Unit of Measure');
            Set_minValue(0);
            Set_maxValue(100000);
            Set_performCalculation(true);
        end;
    end;



Filter by label (Content by label)
showLabelsfalse
showSpacefalse
sorttitle
titleExamples
excerptTypesimple
cqllabel = "bc" and label = "orderlines" and label = "example" and label = "OnAddStepsToAnyLine"

...