Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 15 Current »

Overview

Supported ringscanner devices
RS5100
RS6000

RS6100


The Bluetooth ringscanner is unfortunately not supported by Zebra's pairing software.
In order to make the ringscanner pair with a Zebra device, the following procedure needs to be done.

1. Perform Clean Boot 

  1. Clean boot the device by pressing and holding the Restore Key until the white light appears.
  2. Release the Restore Key, and immediately press it again.
  3. Continue to hold the key down until two beeps indicating a clean boot are heard, and the scanner boot beep sequence is heard.
    This sets the ringscanner back to its factory configuration.

2. Configure the Scanner (only if necessary)

If you are experiencing connectivity issues with your RS5100/RS6100 ringscanner then please attempt the setting below.

After resetting the scanner. Scan the following barcode, to make the RS5100/RS6100 mimic an RS6000.

3. Update the build version on your mobile/tablet device

If you are still experiencing an issue then please update the build version on your mobile/tablet device (Make sure to check the android version on your device).

4. Once the ringscanner can connect to your device

  1. Reboot the scanner by holding the Restore Key down for three seconds, and releasing it.
  2. Reboot the device.
  3. Finally Pair the Device Using the Pairing app on the device.
  4. Once the ringscanner is connected open the DataWedge app
    1. Select the Mobile WMS profile
    2. Go to: Configure scanner settings
    3. Select Scan params
    4. Select Code Id Type
      1. This must be set to "Aim".



  • No labels