Use this event to
Excerpt |
---|
Modfy properties for any single Step from RegistrationCollectorConfigurations. |
...
At time of writing no 'RegistrationCollectorConfiguration's exists in ReferenceData for the standard Mobile WMS, meaning you can not use this event to modify standard steps. The standard workflow uses steps defined in Application.cfg (with no ConfigurationKey defined for these steps).
...
Template
[EventSubscriber(ObjectType::Codeunit, Codeunit::"MOB WMS Reference Data", 'OnGetReferenceData_OnAfterAddRegistrationCollectorConfiguration', '', true, true)]
local procedure OnGetReferenceData_OnAfterAddRegistrationCollectorConfiguration(var _Steps: Record "MOB Steps Element")
begin
end;
Example
[EventSubscriber(ObjectType::Codeunit, Codeunit::"MOB WMS Reference Data", 'OnGetReferenceData_OnAfterAddRegistrationCollectorConfiguration', '', true, true)]
local procedure MyOnGetReferenceData_OnAfterAddRegistrationCollectorConfiguration(var _Steps: Record "MOB Steps Element")
begin
with _Steps do
if (ConfigurationKey = 'MyCustomRegistrationCollectorKey') and (Get_name() = 'MyStepName') then
Set_visible(false);
end;
Version History
Version | Changes |
---|---|
MOB5.14 | Introduced |
...